📞 +91 78695 10053 / +91 95886 90930 ✉ vishakha@vezorainternational.com ✉ kush@vezorainternational.com
in f ig
Industrial Automation › Capability 02

Variable Frequency
Drive (VFD)
Engineering & Integration

End-to-end VFD engineering — drive selection, sizing, parameterisation, EMC filter design, brake-resistor sizing and full motor-load commissioning — for pumps, fans, conveyors, mixers, compressors and machine tools from 0.4 kW to 500 kW across ABB, Siemens, Schneider, Danfoss, Yaskawa & Delta drives.

8+
VFD Brands Supported
0.4–500 kW
Power Range Engineered
25%+
Typical Energy Savings
FAT+SAT
Factory & Site Acceptance
🎛️
VFD · Drives · Motors
Sized · Tuned · Commissioned
0.4–500 kWFull power range
🌬️
Pumps & FansSensorless vector
🔄
Conv. & MixersClosed-loop torque
🌐
Profinet / ModbusNetwork-ready
VFD Brands We Engineer On

8 Leading VFD Brands — Full Lifecycle Support

🟥ABBACS580 · ACS880 · ACS355 · DCS
🏭SiemensSinamics G120 · S120 · V20 · MM440
SchneiderAltivar 320 · 630 · 930 · ATV12
🔴DanfossFC 102 · FC 202 · FC 302 · VLT
🔵YaskawaA1000 · GA500 · GA800 · V1000
🔵MitsubishiFR-A800 · FR-D700 · FR-E700
🟢DeltaVFD-MS300 · CH2000 · C2000+
🟠Lenze · Allen-Bradleyi550 · 8400 · PowerFlex 525/755
What We Engineer

Full-Lifecycle VFD & Drive Engineering

From sizing the right drive for a single 5 kW pump to commissioning 500 kW process drives with regen braking — six core engineering capabilities, fully accountable.

01
⚖️

Drive Sizing & Selection

Right drive for the right load — calculated from motor data, load profile, ambient conditions, duty cycle and start/stop frequency. Avoid oversizing waste & undersizing failures.

  • Motor-load profile analysis
  • Constant / variable torque sizing
  • Heavy-duty / overload rating
  • Ambient derating (temp / altitude)
02
🛠️

Programming & Parameterisation

Application-specific drive programming — V/Hz, sensorless vector, closed-loop vector or DTC — with PID, ramps, jog modes, S-curves and start-up routines configured for your process.

  • V/Hz · sensorless vector · CLV · DTC modes
  • PID for pressure/flow/temp control
  • S-curve, multi-step ramp configuration
  • Auto-tune & commissioning macros
03

EMC & Power Quality

EMC compliance is critical — line filters, line reactors, output dV/dt filters and sine-wave filters sized correctly to meet IEC 61800-3 limits and protect motor insulation on long cable runs.

  • EMC filter sizing (Class A / B / C2)
  • Line & load reactors
  • dV/dt & sine-wave output filters
  • Harmonic mitigation & THD audit
04
🌐

Communication & Network Integration

Drive integration into your control system — Profinet, EtherNet/IP, Modbus TCP/RTU, CANopen or Profibus — with PLC function blocks, parameter access & status monitoring.

  • Profinet · EtherNet/IP · Modbus · CANopen
  • PLC function blocks & faceplates
  • Drive monitoring on HMI / SCADA
  • Multi-drive synchronisation
05
📉

Energy Audit & Savings

Most pumps, fans & compressors run far below rated load. Replacing star-delta starters with VFDs typically saves 20–40% energy with payback in 12–24 months — we measure, report and prove the savings.

  • Baseline energy measurement
  • Load-profile data logging
  • VFD vs. throttle / damper savings calc
  • Post-installation savings verification
06
🔋

Soft Starters, DC Drives & Regen

Beyond standard VFDs — soft starters for high-inrush pumps & compressors, DC drives for legacy DC motors, and active-front-end / regenerative drives for hoists & lifts.

  • Soft starters with bypass
  • DC drives (1Q / 2Q / 4Q)
  • Active front-end (AFE) regenerative
  • Brake resistor & chopper sizing
Industries We Automate

VFDs in Action — Across African Industry

From municipal water pumps to mine-shaft conveyors and process-industry mixers — VFDs are the workhorse of efficient electrical drives across every African industrial sector.

💧
PumpsWater, slurry, dosing, vacuum, sewage
🌬️
Fans & BlowersHVAC, induced/forced draft, exhaust
🔄
ConveyorsBelt, screw, drag, apron, modular
🌀
Mixers & AgitatorsProcess tanks, reactors, blenders
🏭
CompressorsAir, refrigeration, gas — soft start
⛏️
Crushers & MillsMining, cement, food milling
🏗️
Hoists & CranesRegen drives, multi-motor sync
🛠️
Machine ToolsSpindle drives, servo-style applications
Our Engineering Process

From Drive Sizing to Energy Savings Verified

Every VFD project follows the same disciplined path — from load profiling and drive sizing through commissioning, tuning and energy savings verification.

1

Load & Site Survey

Motor data, load profile, ambient, duty cycle & supply quality

2

Drive Sizing & Selection

Drive model, EMC filter, reactor, brake resistor, cabling

3

Parameterisation & Programming

V/Hz, vector or DTC config; PID, ramps, comms set-up

4

FAT — Bench Test

Drive bench-tested with motor & load simulation

5

On-Site Commissioning

No-load run, on-load tuning, vibration & current check

6

Energy Audit & Handover

Post-install savings measurement, operator training, AMC

Our Engineering Toolkit

The Drives, Filters & Tools We Engineer With

Multi-Brand Drive Engineering Team

Our drive engineers are experienced across the world's leading VFD brands — ABB, Siemens, Schneider, Danfoss, Yaskawa, Delta & Lenze — so we recommend the right drive for your motor and load, not just one OEM.

Whether you're standardising on ABB ACS880, retrofitting Sinamics G120 across a plant, or upgrading legacy Mitsubishi A700s to A800s, we deliver sizing, supply, parameterisation, commissioning & tuning across every major drive family.

  • 📜
    Brand-neutral recommendations — best-fit drive for your motor/load, ambient, comms standard & existing inventory.
  • 🔄
    Legacy drive replacement — Siemens MM440→G120, ABB ACS550→ACS580, Mitsubishi A500→A800, Yaskawa V1000→GA500.
  • 📊
    Energy audit reports — kWh-baseline, load-profile data & verified post-installation savings.
  • 🛡️
    EMC & insulation protection — line/load filter sizing, dV/dt & sine filters for long cables and old motors.

🎛️Standard VFD Series

ABB ACS580 / ACS880Siemens Sinamics G120 / V20Schneider Altivar 320 / 630Danfoss FC 102 / FC 202Yaskawa GA500 / GA800Mitsubishi FR-A800Delta MS300 / C2000+Allen-Bradley PowerFlex 525 / 755

Soft Starters & DC Drives

ABB PSE / PSTXSiemens 3RW soft starterSchneider Altistart 22 / 48Danfoss MCD 600ABB DCS800Siemens 6RA80 DC Master

🔋Filters, Reactors & Brake Resistors

EMC Class A/B filtersLine reactors 2–5%Output dV/dt filtersSine-wave output filtersBrake choppersBrake resistors (custom)

🌐Drive Communication

ProfinetEtherNet/IPModbus TCP / RTUCANopenProfibus DPEtherCATCC-Link

📊Engineering & Tuning Tools

ABB Drive ComposerSiemens Starter / StartdriveSoMove (Schneider)MCT 10 (Danfoss)DriveWorksEZ (Yaskawa)FR Configurator (Mitsubishi)
Why Vezora for Automation Engineering

What Sets Our VFD & Drive Engineering Apart

🎓
Multi-Brand Drive Specialists

ABB Drive Composer, Siemens Sinamics, Danfoss MCT 10, Yaskawa DriveWorks — engineers across all major drive families.

📚
Right Drive for the Right Load

We size based on motor data, load profile, ambient and duty cycle — no over-spec waste, no under-spec failures.

🌍
Designed for African Grid & Climate

EMC, derating, ambient temperature, voltage tolerance, dust ingress all factored — drives don't trip on hot afternoons.

📞
24/7 Remote Drive Support

Secure VPN remote-access into drive parameters and PLC — most trips diagnosed within 1 hour without travel.

📋
Energy Savings Audited & Verified

Pre- & post-installation kWh measurement & reporting — energy savings claims are proven, not marketed.

💰
Drive Supply + Engineering Bundle

We supply the drive, EMC filter, reactor, panel build, programming & commissioning — single vendor, single accountability.

Discuss Your Project

Get a VFD Sizing & Engineering Proposal Within 5 Working Days

Tell us about your application — pump, fan, conveyor, mixer, hoist or process drive. Our drive engineers will respond with sizing, brand recommendation, EMC scope and full proposal with CIF / on-site pricing.

  • No-cost initial scoping & platform recommendation
  • Detailed proposal within 5 working days
  • 🌍Adapted to your platform standard & site conditions
  • 📋Includes FAT, SAT, training & documentation in scope
  • 🛡️NDA available for confidential project discussions
📞 +91 78695 10053 (India — WhatsApp) vishakha@vezorainternational.com

VFD & Drive Project Enquiry

Outline your application — we'll respond with detailed sizing, drive selection & commercial scope within 5 working days.

🔒 Request NDA First

🔒 Project details are confidential. NDA available on request before scope discussion.

WhatsApp Chat on WhatsAppReply within minutes